Summary0001461: Inaccurate frequency reading on some frequencies when used with TenTec Omni VII
DescriptionWhen used with TenTec Omni VII

100% reproducible error with HRD reading rig frequency.
Frequencies between 14,028,032 and 14,028,302 are read incorrectly by HRD. The
misread values are stable and 100% repeatable.
For example: 14,028,033 reads as 17,629,184 and 14,028,034 reads as 34,406,400.
Steps To ReproduceTune Omni VII to a frequency between 14,028,032 and 14,028,302 and observe
reading on HRD rig control screen
Additional InformationReported by kc4mm

The frequencies that fail are ones that contain an 0x0D, better known
as a carriage return in the ASCII world, and is also used as the terminating
character for the frequency data.
TagsOmni VII, Ten-Tec
ModuleRig Control
Sub-Module(select)
Testing

Activities

There are no notes attached to this issue.

Issue History

Date Modified Username Field Change
2013-12-23 21:44 WA9PIE New Issue
2013-12-23 21:44 WA9PIE Status new => assigned
2013-12-23 21:44 WA9PIE Assigned To => Support
2013-12-24 09:30 WA9PIE Project 2 - Next Dev List (Holding Area) => @5@
2014-02-02 13:51 WA9PIE Release => (select)
2014-02-02 13:51 WA9PIE Module => (select)
2014-02-02 13:51 WA9PIE Sub-Module => (select)
2014-02-02 13:51 WA9PIE Report Build => (select)
2014-02-02 13:51 WA9PIE Assigned To Support =>
2014-02-02 13:51 WA9PIE Status assigned => acknowledged
2014-02-02 13:51 WA9PIE Summary Inaccurate frequency reading on some frequencies when used with TenTec Omni VII => Bug: Inaccurate frequency reading on some frequencies when used with TenTec Omni VII
2014-02-02 13:51 WA9PIE Description Updated View Revisions
2014-02-02 13:51 WA9PIE Steps to Reproduce Updated View Revisions
2014-02-02 13:51 WA9PIE Additional Information Updated View Revisions
2014-02-02 16:40 WA9PIE View Status private => public
2015-09-17 13:08 WA9PIE Module (select) => Rig Control
2015-09-17 13:17 WA9PIE Category Rig Control => Bug
2015-09-17 13:19 WA9PIE Project @5@ => 1 - Backlog
2015-09-25 18:14 WA9PIE Fix Build => (select)
2015-09-25 18:14 WA9PIE Summary Bug: Inaccurate frequency reading on some frequencies when used with TenTec Omni VII => Inaccurate frequency reading on some frequencies when used with TenTec Omni VII
2018-11-28 01:25 WA9PIE Tag Attached: Ten Tec Omni VII
2018-11-29 01:01 WA9PIE Tag Renamed Ten Tec Omni VII => Ten-Tec Omni VII
2018-11-30 23:33 WA9PIE Tag Attached: Omni VII
2018-11-30 23:33 WA9PIE Tag Attached: Ten-Tec
2018-11-30 23:33 WA9PIE Tag Detached: Ten-Tec Omni VII