Summary0002297: IC-7800 Power meter in Rigcontrol shows percentage not Watts
DescriptionCan we do a conversion, showing Watts for the IC-7800?
At this time it shows 100 when the set does 200 Watts. (That 100 is 100%)
Steps To ReproduceN/A
Additional InformationTicket 564616
TagsIC-7800, ICOM
ModuleRig Control
Sub-ModuleRadio Support
Testing

Activities

PD9FER

2017-12-20 14:33

updater   ~0004291

Info:

CI-V command 15 Sub 11 Data 000 to 0255
Read RF power meter
(0000=0 W, 0143=100 W, 0212=200 W)