View Issue Details

IDProjectCategoryView StatusLast Update
00036302 - Next Dev List (Holding Area)Bugpublic2020-01-26 04:56
Reporterg3ucqAssigned To 
PriorityhighSeveritymajorReproducibilityalways
Status newResolutionopen 
PlatformPCOSWindowsOS Version10 64 bit Home
Summary0003630: Clicking the Data Controller tab in DM780 creates a minidump file
DescriptionClicking on the Data Controller tab on the Radio pane in DM780 creates a minidump file and DM780 closes.
Steps To ReproduceOpen DM780, it makes no difference if Rig Control is running or not.
Open the Radio pane and click on the Data Controller tab bottom right.
A minidump file will be created and clicking on OK closes DM780 incorrectly.
Additional InformationThis occurs with versions v6.7.0.256 through to .258.
TagsNo tags attached.
ModuleDM780
Sub-Module(select)
TestingNot Started

Activities

g3ucq

2020-01-26 04:42

updater  

DigitalMaster_20200126_102449.7z (58,639 bytes)

g3ucq

2020-01-26 04:56

updater   ~0009554

Apologies. This is the same bug as I reported on 27 October 2019 Mantis 0003522.

Issue History

Date Modified Username Field Change
2020-01-26 04:42 g3ucq New Issue
2020-01-26 04:42 g3ucq File Added: DigitalMaster_20200126_102449.7z
2020-01-26 04:56 g3ucq Note Added: 0009554